| Sign In | Join Free | My xxjcy.com |
|
Brand Name : SUNTECHMACH
Model Number : DSY-60
Certification : ISO9001
Place of Origin : ZHEJIANG, CHINA
MOQ : 1SET
Price : Negotiable
Payment Terms : T/T
Supply Ability : 10000PCS/MONTH
Delivery Time : 10working days
Packaging Details : One piece/carton
Pressure range : 0-60 bar (0-6.0 MPa, 860 psi)
Voltage : 110V / 220V
G.W./N.W. : 13.5/12 kg
Connection : 1/2" BSPP
Flow volume : 180 L/H (2.9 L/min)
Name : Electric Hydraulic Test Pump
Motor power : 250W induction type
The SUNTECHMACH DSY60 electric hydraulic test pump is designed for quick and exact compression testing and leak detection in heating, compressed air, refrigeration, oil installations, sprinkler systems and other small bore pipe applications. Driven by a 250W induction motor, it pressurizes pipe systems up to 60 bar (860 psi) automatically — no manual pumping. Compact and portable (13.5 kg), with 1/2" BSPP connections, it is ready to use on PPR, PVC and PE pipe installation jobs.
| THE PROBLEM | HOW WE SOLVED IT |
|---|---|
| Manual test pumps are slow and tiring | 250W electric motor pressurizes automatically to 60 bar |
| Small leaks are hard to find in heating/sprinkler systems | Precise pressure testing with clear pressure gauge reading |
| Test pumps are bulky to carry on site | Compact design, only 13.5 kg, plastic-box packed |
| Fittings don't match site pipes | Standard 1/2" BSPP connection, works with common pipe fittings |
Key Features
Technical Specifications
| Field | Content |
|---|---|
| Model | DSY-60 |
| Pressure range | 0-60 bar (0-6.0 MPa, 860 psi) |
| Flow volume | 180 L/H (2.9 L/min) |
| Motor power | 250W induction type |
| Voltage | 110V / 220V |
| Connection | 1/2" BSPP |
| G.W./N.W. | 13.5/12 kg |
| Packing size | 40 x 30 x 29 cm |
| Package | Plastic box, 1 pc/carton |
What's Included
Applications
Packaging & Quality Assurance
One piece per carton with plastic box inside. PP fittings packed in nylon bags. ISO9001 quality system; every pump tested before shipment.
After-Sales Support
Operation Guide
Common Faults & Solutions
| Common faults | Reasons | Solutions |
|---|---|---|
| Pump cannot absorb water | Filter clogged; air in pump; water level too low | Clean filter; add water from inlet; keep suction port submerged |
| Water leaks at pump bottom | Sealing ring damaged | Replace the sealing ring |
| Pressure gauge damaged | Pressure regulating knob turned to the end | Always loosen the knob before starting; do not over-tighten |
| No pressure build-up | Inlet suction leaks; valve open | Check suction joints; close the control valve before testing |
| Motor does not start | Power/leakage protection tripped; wrong wiring | Check socket and wiring; reset leakage protection |